CT image integration into three-dimensional electroanatomical mapping system on guidance for catheter ablation of atrial fibrillation
10.3969/j.issn.1673-8225.2009.52.009
- VernacularTitle:三维电解剖标测系统与CT影像融合指导心房颤动导管消融
- Author:
Fuli HU
;
Changsheng MA
;
Jianzeng DONG
;
Xingpeng LIU
;
Deyong LONG
;
Ronghui YU
;
Ribo TANG
;
Xiaomei LI
- Publication Type:Journal Article
- From:
Chinese Journal of Tissue Engineering Research
2009;13(52):10251-10255
- CountryChina
- Language:Chinese
-
Abstract:
BACKGROUND:Circumferential pulmonary vein antrum ablations guided by CARTO system or integration of a computed tomographic or magnetic resonance imaging scan (CARTO-Merge) are two main locating methods.Theoretically,CARTO-Merge provides a detailed appreciation of the pulmonary vein anatomy,however,whether it can improve the safety and success of catheter ablation of atrial fibrillation remains uncertainly.OBJECTIVE:To explore the effect of CT image integration into three-dimensional (3D) electroanatomical mapping system on clinical outcomes of catheter ablation of atrial fibrillation.DESIGN,TIME AND SETTING:The randomized contrast observation was performed at Department of Cardiology of Beijing Anzhen Hospital from October 2005 to May 2007.PARTICIPANTS:A total of 93 patients with drugs refractory,paroxysmal atrial fibrillation who underwent circumferential pulmonary vein antrum ablation.METHODS:All patients underwent circumferential pulmonary vein antrum ablation using irdgated radiofreguency ablation with the endpoint of electrical isolation.Ablation was guided by 3D mapping alone in 50 patients (CARTO group) or by CT image integration in 43 patients (CARTO-Merge group).MAIN OUTCOME MEASURES:Procedure-related parameters,such as procedure duration,fluoroscopy duration,cumulative success rate and complication,were compared between the two groups.RESULTS:Pulmonary veins were isolated in all patients.After (12.6±2.9) months follow-up,73 (78.5%) patients did not have recurrence of atrial fibrillation at 3 month after the procedure.The fluoroscopy time in CARTO group was significant longer than that in CARTO-Merge group (P<0.05).The mean procedure duration,radiofrequency ablation duration,procedure-related complication and cumulative success rate were comparable between the 2 groups.CONCLUSION:Circumferential pulmonary vein antrum ablation guided by 3D mapping alone or by CT integration had similar safety and success rate in paroxysmal atrial fibrillation patients.But CT integration,which facilitated to a detailed representation of the anatomy of left atrium,is associated with reduced fluoroscopy duration.