Establishment of 3-dimensional finite element model of human knee joint and its biomechanics
10.3969/j.issn.1672-7347.2010.01.012
- VernacularTitle:膝关节三维有限元模型的建立及生物力学分析
- Author:
Ping YUAN
;
Wanchun WANG
- Publication Type:Journal Article
- Keywords:
knee joint;
finite element;
biomechanics
- From:
Journal of Central South University(Medical Sciences)
2010;35(1):85-89
- CountryChina
- Language:Chinese
-
Abstract:
Objective To establish a 3-dimensional (3-D) finite element knee model in healthy Chinese males, to verify the validity of the model, and to analyze the biomechanics of this model under axial load, flexion moment, varus/valgus torque, and internal/external axial torque. Methods A set of consecutive transectional computerized tomography images of normal male knee joints in upright weight-bearing position was selected. With image processing and inversion technology, the 3-D finite element model of the normal knee joint was established through the software ABAQOUS/STANDARD Version-6.5.Biomechanical analysis of this model was processed under axial load, flexion moment, varus/valgus torque, and internal/external axial torque.Results A 3-D finite element model of healthy Chinese males was successfully established. The ranges of motion of varus and valgus were both small and the difference between them has no statistical significance (P>0.05). The motion of internal and external rotation of the knee took place only in flexion situation.The range of motion of external rotation was larger than that of internal rotation in the same knee (P<0.05).Conclusion The 3-D geometrical model of the knee resembles the actual knee segments. It can immitate the knee response to different loads. This model could be used for further study on knee biomechanics.