Preliminary Application of DSA Parametric Imaging in Evaluating the Hemodynamics of Brain after Interventional Therapy for Stenosis of Carotid Artery
10.3969/j.issn.1002-1671.2010.02.025
- VernacularTitle:颈动脉狭窄介入治疗前后的DSA血流动力学参数评价
- Author:
Qiang ZHANG
;
Huaijun LIU
;
Lianyi LAN
;
Zengpin LIU
;
Tiegang WANG
;
Lin ZHAO
- Publication Type:Journal Article
- Keywords:
rotid artery stenosis;
stent;
DSA;
interventional radiology
- From:
Journal of Practical Radiology
2010;26(2):251-254
- CountryChina
- Language:Chinese
-
Abstract:
Objective To evaluate the changes of cerebral perfusion and hemodynamics in the patients with mono-carotid artery stenosis after stenting with the technique of DSA parametric imaging. Methods 15 patients with mono-carotid artery stenosis(the stenosis>75%) undergone carotid stenting were choosed. Digital subtraction imagines of diplo-carotid arteries were acquired before and after operation, then the imagines were processed by special soft ware in personal computer. The region of interest (ROI)were selected in the brain,internal carotid artery and superior sagittal sinus separately, the time-gray scale curves of the ROIs were drawn with the soft ware, from which,then acquired the following parameters from the time-gray scale curves,the largest gray values of brain in disordered side pre-and post-operation, and the parameters including peak value (PV), mean transit time (MTT) ,time to peak (TP), time of appearance to the peak , the max slope rate of the curve and relative time of cerebral circulation were also evalua-ted, respectively. The imaging speed was 7.5 pictures per second. The results were statistically evaluated by using matched-t test. Results Before the stenting, the values of the parameters peak value, the max slope rate of the curve,TP,MTT,relative time of cer-ebral circulation were 108.20±5.58 , 1.23±0.37 , (4.78±0.24)s , (8.20±0.42)s and(4.92±1.03)s , respectively; after the stenting , the values of the parameters above-mentioned were 114.20±7.58, 2.01±0.36, (4.14±0.40)s, (3.55±0.56)sand(4.18±0.89) s , respectively, the difference of the parame-ters above-mentioned pre-and post-operation were statisti-cally significant (t=5.97 , 8.00 , 0.21 , 10.21 , 10.12 and 4.14,P<0.05). Before and after operation, the values of time of appearance to the peak were (5.39±0.24) s and)(5.37±0.78) s , respectively , there was no statistical significance (t=0.21, P> 0.05). Conclusion DSA parametric imaging can be used to evaluate the changes of cerebral perfusion and hemodynamics before and after arterial stenting.