Treatment of olecranon fracture with biodegradable tension band in 9 cases
10.3969/j.issn.1673-8225.2010.08.040
- VernacularTitle:生物可吸收张力带治疗尺骨鹰嘴骨折9例
- Author:
Xin WEI
;
Guixin SUN
;
Lijun LI
;
Jun TAN
- Publication Type:Journal Article
- From:
Chinese Journal of Tissue Engineering Research
2010;14(8):1495-1498
- CountryChina
- Language:Chinese
-
Abstract:
BACKGROUND: Internal fixations with plate and screw or K-wira tension band are widely used in treating olecranon fracture; however, the internal fixations need to remove by a second surgery. OBJECTIVE: To retrospective analyze the therapeutic effect of treating olecranon fracture using biodegradable tension band. METHODS: Nine olecranon fracture patients received at the Shanghai East Hospital of Tongji University from July 2006 to April 2009 were selected. All patients were treated by biodegradable tension band fixation which comprises absorbable screw and absorbable suture. Elbow joint functional exercises were performed at 3 weeks after plaster extema! fixation. The patients were followed up for 12 months, and the therapeutic effect was measured by X-ray films and Mayo score of elbow joint function. RESULTS AND CONCLUSION: Imaging examination showed that the fracture healing well in all cases, and the fracture line was blurred. No ulnar nerve compression, fracture, or fracture displacement could be seen. Biodegradable tension band fixation can provide adequate intensity for functional exercises, which has the virtue of effective fixation without a second surgery to remove fixation. It is believed to be a good method for the treatment of olecranon fractures.