Accuracy study of using CT to delineate tumor target volume of thoracic esophageal carcinoma
- VernacularTitle:应用CT勾画胸段食管癌肿瘤靶区准确性研究
- Author:
Junqiang CHEN
;
Jianji PAN
;
Minqiang CHEN
;
Yunbin CHEN
;
Kunshou ZHU
;
Xiongwei ZHEN
;
Weining LI
;
Junxin WU
;
Wenjuan CHEN
;
Sufang QIU
;
Jinrong XIAO
- Publication Type:Journal Article
- Keywords:
Esophageal neoplasm;
Surgery;
Pathology;
Tomography,X-ray computed;
Esophagram
- From:
Chinese Journal of Radiation Oncology
2008;17(2):90-92
- CountryChina
- Language:Chinese
-
Abstract:
Objective To compare the accuracy of CT with other methods to measure the length of thoracic esophageal carcinoma. Methods 598 patients with thoracic esophageal squamous carcinoma were enrolled in this study.All the patients received three-field(cervical,thoracic:and abdominal)radical surgery without pre-operative radiotherapy or chemotherapy.The length of each Iesion was recorded and compared by measuring intraoperative specimen,formalin-fixed specimen,X-ray barium meal examination and CT,respectivelv. Results By the measurement of intraoperative specimen,formalin-fixed specimen,Xray barium meal examination and CT,the mean lengths of lesion were(5.22±1.94),(4.28±1.71),(5.12±1.92)and(6.71±2.52) cm,respectively.The measured length was significantly different between intraoperative specimen and formalin-fixed specimen or CT(t=16.01,P<0.01;t=-15.54,P<0.01),but not between intraoperative specimen and X-ray barium meal examination(t=1.62,P>0.05).The measured lengths gradually decreased in the order of CT,intraoperative specimen,X-ray bailam meal examination and formalin-fixed specimen.For different pathological type(except intracavitary type)and different T staging,there was significant difference in lesion length between intraoperative specimen and CT(P<0.05),but not between intraoperative specimen and X-ray barium meal examination(P>0.05). Conclusions The length of esophageal carcinoma measured by intraoperative specimen is shorter than by CT,but longer than by X-ray barium meal examination.Specimen could shrink after foriBalin fixation.X-ray barium meal and other examinations should be referred when using CT to delineate tumor target volume of esophageal carcinoma for radiotherapy.