Effect of various methods determining lung volume and fraction dose on the lung dose-volume parameters
- VernacularTitle:不同肺体积确定方法和剂量分割方法对肺剂量体积参数的影响
- Author:
Liming XU
;
Chengjun LI
;
Wenyong TAN
;
Jingguo FU
;
Xing YANG
- Publication Type:Journal Article
- Keywords:
Lung neoplasms/radiotherapy;
Lung volume;
CT value;
Dose-volume parameter
- From:
Chinese Journal of Radiation Oncology
2008;17(2):106-108
- CountryChina
- Language:Chinese
-
Abstract:
Objective To study the effect of various methods determining lung volume and fraction dose on the lung dose-volume parameters for lung cancer patients. Methods Twenty patients with lung cancer were rantdomly enrolled into our study and the plan of three dimensional eonformal radiation therapy(3DCRT)was designed by Varian Eclipse TPS.The lung volumes and the dose-volume parameters were measured under CT value of-300- -980, -400- -980 and -500- -980.Under CT value of -400- -980,total lung volumes were confirmed.The dose-volume parameters of V30,V20,V10 and mean lung dose(MLD)were reevaluated after GTV,CTV and PTV were subtracted from the total lung volumes and when the fraction dose was elevated from 2.0 Gy to 10.0 Gy. Results When the CT value ranged from-300--980 to-500--980,the median reduction of the total lung volumes(-9.10%)was significantly higher than that of V30,V20,V10 and MLD(-3.18%,-1.13%,0.82%and-0.79%,respectively).When the total lung volume was fixed at CT value of-400--980,the alterations of V30,V20,V10 and MLD became more apparent as the increase of the subtracted lung volume,among which the alteration of V30 was most significant while V10 the least.Among five cases with a fixed total dose of 60 Gy and PTV less than 140 cm3,the V30,V20,V10 and MLD were increased to a similar extent(about 40%)when the fraction dose was increased from 2.0 Gy to 10.0 Gy.MLD was increased(36%)when the fraction dose was above 6.0 Gy. Conclusions When CT value ranges from-300- -980 to-500- -980,the total lung volume is influenced most.The alteration of V30,being statistically significant,might have some significance but is not enough to determine the plan of radiotherapy clinically.The alteration of V20、V10 and MLD is not statistically significant.When the overlapped target volume is subtracted from the total lung volumes,the alteration of V30 is the most sign:tifhcant while V10 the least.The fraction dose,being the most consuming factor(>10%)when comparing with the CT valHe and targeted volume,can significantly influence the dose-volume parameter.