Puncture angle choice of ultrasound guided automatic kidney biopsy in 518 cases
- VernacularTitle:超声引导下自动肾活检穿刺角度的选择
- Author:
Suqi JIANG
;
Hongguang ZHENG
;
Junying CAO
;
Hongli WU
;
Wei WANG
;
Huihong CAI
- Publication Type:Journal Article
- Keywords:
Ultrasonography;
Kidney;
Biopsy;
Angle
- From:
Chinese Journal of Primary Medicine and Pharmacy
2008;15(7):1151-1152
- CountryChina
- Language:Chinese
-
Abstract:
Objective To elevate the achievement rate of kidney biopsy puncture through the analysis of puncture angle choice of ultrasound guided automatic kidney biopsy in 518 patients. Methods Under the guidance of color Doppler ultrasound,using the 3.5MHz probe with probe holder,we performed kidney biopsy in the degrees of 40°(group X),45°(group Y),60°(group Z) and 70°(group P) with the horizontal plane. Resnlts The total achievement ratio is 100 %. The one time success rate in group Y and group Z is 100 % (group Y, 164/164 ; group Z, 186/186) ;group X is 4.8% (22/46) ;group P is 84.4% (103/122).Conclusion The automatic kidney biopsy an- gle under the guidance of ultrasound should be between 45° and 60° with the horizontal plane which is safe and has higher achievement ratio. In the meantime, complications can be avoided.