Dosimetric study on conventional mantle-field irradiation and intensity-modulated radiotherapy for Hodgkin's lymphoma
10.3760/cma.j.issn.1004-4221.2009.02.110
- VernacularTitle:霍奇金淋巴瘤斗篷野常规放疗与调强放疗计划剂量学研究
- Author:
Ruozheng WANG
;
Youxiang HOU
;
Juwu WANG
;
Suling XU
;
Fuer WU
;
Duoming WANG
- Publication Type:Journal Article
- Keywords:
Lymphoma/conventional radiotherapy;
Lymphoma/intensity modulated radiothera-py;
Treatment planning system;
Dosimetry
- From:
Chinese Journal of Radiation Oncology
2009;18(2):110-113
- CountryChina
- Language:Chinese
-
Abstract:
Objective To compare the dose distribution of mantle-field radiotherapy using conven-tional radiotherapy(CRT) and four intensity-modulated radiotherapy(IMRT) techniques in stage Ⅰ and Ⅱ Hodgkin's lymphoma(HL). Methods Ten patients with patholocally proved early stage HL underwent CT simulation. Then both CRT and IMRT planning performed using ECLIPS treatment planning system(TPS). The dosimetric parameters of different irradiation plans were analyzed, including conformal index (CI), homo-geneity index (HI), D95 and V95 of planning target volume (PTV), Dmax,Dmean,Dmin,V5,V10,V20 and V30 of the lung, as well as Dmax of the spinal cord. Results The isodose distribution and homogeneity of PTV were better in IMRT plans when compared with CRT plans. Target coverage, target dose conformity and homogene-ity were similar among all the four IMRT techniques. The V30 of the lung using IMRT was lower than using CRT,but the low-dose volume of the lung was higher. Among the four IMRT technique plans,the lung V20 and V30 were lower in plans with more-field technique,but the V5 and V10 were higher. The Dmax of the spinal cord using IMRT was all lower than that using CRT. Conclusions IMRT is better than CRT in target cov-erage, conformity, homogeneity and normal tissue sparing, especially in protecting the spinal cord and decrea-sing high-dose lung volume,though the low-dose lung volume is higher. Seven-field IMRT technique for man-de-field radiotherapy is recommanded.