Impact of CT scanning condition on the precision and accuracy of target position
10.3760/cma.j.issn.1004-4221.2009.02.142
- VernacularTitle:CT扫描对靶点位置精确度影响分析
- Author:
Xianfu LI
;
Bangxian TAN
;
Mi LIU
;
Yujun LUO
;
Yeqin ZHOU
;
Jin HU
;
Daiyuan MA
- Publication Type:Journal Article
- Keywords:
CT scanning;
Localizing;
Precision and accuracyDOI : 10. 3760/cma. j. issn. 1004-4221. 2009.02. 142
- From:
Chinese Journal of Radiation Oncology
2009;18(2):142-145
- CountryChina
- Language:Chinese
-
Abstract:
Objective To study the effect of CT scanning condition on the target position coordinate with WIMRT radiotherapy planning system using the" Z" form localizing frame. Methods The whole Head Phantom containing three metal targets was scanned under the following conditions: localizing frame transver-sally tilting, CT gantry tilting and localizing frame axially tilting. Then the three target coordinates were com-puted respectively and compared with those under the standard condition. Results The height and width of coordinate under the localizing frame transversally tilting condition deviated from those under the standard scanning condition,which was in an angle dependent manner. On the other hand ,a tendency was shown that the greater the absolute height value of the targets coordinate, the greater the width value deviation. And so was the relation between the absolute width value of the coordinate and height value deviation. If CT gantry angle was not zero degree or localizing frame axis is not in the same line with the CT bed moving direction, the calculated longititude value of the targets coordinate was mainly affected. Conclusions CT scanning must be performed strictly under the standard localizing scanning condition by a proficient physicist.