Clinical value of transvaginal Doppler ultrasound in diagnosing ectopic oviduct-pregnancy
10.3760/cma.j.issn.1008-6706.2009.03.046
- VernacularTitle:经阴道超声诊断输卵管妊娠的临床价值
- Author:
Yun TANG
;
Cheng TANG
;
Zhen HUANG
;
Hongshen DONG
;
Maoen DENG
;
Yuhua YU
;
Haoliang HUANG
- Publication Type:Journal Article
- Keywords:
Pregnancy,tubal;
Ultrasonography
- From:
Chinese Journal of Primary Medicine and Pharmacy
2009;16(3):472-473
- CountryChina
- Language:Chinese
-
Abstract:
Objective To explore clinical value of transvagiTIa ultrasound in diagnosis of cctopie oviductpregnancy.Methods EUB-2000 ultrasound diagnosis meter was used,the vagina probe head frequency is 5~10MHz,after the vagina to the womb,the double-side ovary,the double side oviduct and its periphery organizes to carry on omni-direetionally sweeps looks up.Results Transvagina ultrasound diagnosis ectopic pregnancy center oviduct pot abdomen pregnancy 158 cases,the oviduct canyon department 4 cases,between the oviduct the nature department pregnancy 2 cases,all pass through the cefioseope of our hospital.Coincidence rate was 100%.Conclusion Transvagina ultrasound diagnosis ectopie pregnancy is one of most accurate ultrasound diagnosis methods presendy,suggested various basic units hospital widely develops.