Study on the approximal side angle of carotid plaques in patients with cerebral infarction using ultrasonography
10.3760/cma.j.issn.1004-4477.2009.12.009
- VernacularTitle:超声对脑梗死患者颈动脉软斑块近心端角度的研究
- Author:
Pintong HUANG
;
Li WANG
;
Xiaojing ZHANG
;
Xinqiao TIAN
;
Haiyan SUN
;
Xiaotong WANG
;
Chunpeng ZOU
;
Fuguang HUANG
- Publication Type:Journal Article
- Keywords:
UItrasonography;
Brain infarction;
Carotid stenosis;
Atherosclerosis
- From:
Chinese Journal of Ultrasonography
2009;18(12):1040-1042
- CountryChina
- Language:Chinese
-
Abstract:
Objective To assess the value of approximal side angle of carotid atherosclerotic plaques in patients with cerebral infarction by ultrasonography.Methods One hundred and seventy six patients with carotid atherosclerotic plaques were examined with uItrasonography and divided into two groups:cerebral infarction group (n=67)and none cerebral infarction group(n=109).Vessel area and residual lumen area of carotid artery were measured in axial view using linear probe.Area stenosis rate was calculated.The approximal side angle and thickness of plaque were measured respectively.The results of two groups were compared.Results The approximal side angle of plaque of cerebral group was significantly higher than that of none cerebral infarction groups(P<0.05).The sensitivity and specificity for approximal side angle of plaque(cutoff value:13.0°)were 79.1%,71.6%,respectively.There were no significant difference of area stenosis rate and plaque thickness between two groups(P>0.05).Conclusions The approximal side angle of plaque can be regarded as a novel index to assess the stability of plaque.