Comparative study between off-pump and on-pump of coronary artery bypass grafting
10.3760/cma.j.issn.1673-4904.2010.02.004
- VernacularTitle:非体外循环和体外循环冠状动脉旁路移植术的临床对比研究
- Author:
Xu CAO
;
Qiang XIE
;
Ming JING
;
Meng LI
;
Xuetao BAI
;
Hongwei JIANG
- Publication Type:Journal Article
- Keywords:
Coronary artery bypass,off-pump;
Complications
- From:
Chinese Journal of Postgraduates of Medicine
2010;33(2):9-10
- CountryChina
- Language:Chinese
-
Abstract:
Objective To compare the clinical effect of off-pump coronary artery bypass grafting (eft-pump CABG)and on-pump coronary artery bypass grafting(on-pump CABG).Methods The clinical dates of 152 cases with coronary artery bypass grafting(off-pump CABG group 85 cases,on-pump CABG group 67 cases)were received from June 2005 to December 2008,the preoperative dates,postoperative mortality and the rate of complication were compared between two groups.Results The preoperative dates of two groups were no significant difference(P>0.05);2 cases(2.35%)were died in off-pump CABG group and 13 cases(15.29%)had complications in off-pump CABG group;9 cases(13.43%)were died in on-pump CABG group and 25 cases(37.31%)had complications in on-pump CABG group.The mortality and the rate of complication in off-pump CABG group was significantly less than that in on-pump CABG group.it was significant difference(P<0.01).Conclusion Off-pump CABG is safe therapy of mieosurgieal operation.