The impact of respiratory motion and active breathing control on the displacement of target area in patients with gastric cancer treated with post-operative radiotherapy
10.3760/cma.j.issn.1004-4221.2010.02.013
- VernacularTitle:胃癌术后放疗中呼吸运动及主动呼吸控制对靶区移动影响分析
- Author:
Xiaoli YU
;
Zhen ZHANG
;
Weilie GU
;
Weigang HU
;
Ji ZHU
;
Gang CAI
;
Guichao LI
;
Shaoqin HE
- Publication Type:Journal Article
- Keywords:
Gastric neoplasms/radiotherapy;
Radiotherapy,postoperative;
Free breathing;
Active breath control
- From:
Chinese Journal of Radiation Oncology
2010;19(2):131-134
- CountryChina
- Language:Chinese
-
Abstract:
Objective To assess the impact of respiratory motion on the displacement of target area and to analyze the discrimination between free breathing and active breathing control (ABC) in patients with gastric cancer treated with post-operative radiotherapy. Methods From January 2005 to November 2006, 22 patients with post-operatively confirmed gastric cancer were enrolled in this study. All diseases were T_3/ N +, staging Ⅱ - Ⅳ. Patients were CT scanned and treated by radiation with the use of ABC. Image J software was used in image processing, motion measurement and data analysis. Surgical clips were implanted as fiducial marks in the tumor bed and lymphatic drainage area. The motion range of each clip was measured in the resultant-projection image. Motions of the clips in superior-inferior (S-I), right-left (R-L) and anterior-posterior (A-P) directions were determined from fluoroscopy movies obtained in the treatment position. Results The motion ranges in S-I, R-L and A-P directions were 11.1 mam, 1.9 mm and 2.5 mm (F = 85.15, P = 0. 000) under free breathing, with 2.2 mm, 1.1 mm and 1.7 nun under ABC (F = 17.64, P = 0. 000), and the reduction of motion ranges was significant in both S-I and A-P directions (t = 4.36, P = 0. 000;t = 3.73,P = 0.000). When compared with under free-breathing, the motion ranges under ABC were kept unchanged in the same breathing phase of the same treatment fraction, while significant increased in different breathing phase in all three directions (t = - 4.36, P = 0. 000; t = - 3.52, P = 0.000; t =-3.79, P = 0. 000), with a numerical value of 3.7 mm, 1.6 mm and 2.8 mm, respectively (F = 19.46, P = 0. 000) . With ABC between different treatment fractions , the maximum displacements were 2.7 mm, 1.7 mm and 2.5 mm for the centre of the clip cluster (F =4.07,P =0. 019), and were 4.6 mm, 3.1 mm and 4.2 mm for the clips (F =5.17 ,P =0.007). The motion ranges were significant increased in all the three directions (t = - 4.09, P=0.000 ; t =-4.46, P = 0.000 ; t = - 3.45, P =0.000). Conclusions In the irradiation of post-operative gastric cancer, the maximum displacement of organ motions induced by respiration is in S-1 direction and the minimum in R-L direction under free breathing. The use of ABC can reduce the motions significantly in S-I and A-P directions, and the same changes exist in both inter-and intra-fraction treatment.