The feasibility and accuracy of enhanced MR pulmonary perfusion imaging in evaluating therapeutic effect of pulmonary embolism
10.3760/cma.j.issn.1005-1201.2010.05.007
- VernacularTitle:MR增强肺灌注成像对肺动脉栓塞治疗疗效评价的可行性及准确性
- Author:
Nana WANG
;
Biao Lü
;
Zhaoqi ZHANG
;
Xiaoyong HUANG
;
Weiyong YU
;
Hongzhi MI
;
Dongxu LU
- Publication Type:Journal Article
- Keywords:
Pulmonary embolism;
Magnetic resonance angiography;
Radionuclide imaging
- From:
Chinese Journal of Radiology
2010;44(5):479-483
- CountryChina
- Language:Chinese
-
Abstract:
Objective To investigate the feasibility and accuracy of enhanced magnetic resonance pulmonary perfusion imaging(MRPP) in the diagnosis and follow-up of pulmonary embolism(PE). Methods Sixty patients suspected of PE underwent MRPP. Twenty-seven patients also underwent radionuclide perfusion imaging. 22 patients repeated MRPP examination after 3 day to 1 month anticoagulation or thrombolytic therapy. The feasibility and accuracy of MRPP in the diagnosis and follow-up of PE were evaluated according to the transformation rate of signal (TROS), time-signal curve and some parameters of main pulmonary artery(such as peak value of flow,mean flow velocity and flow rate). The t test and rank sum test were used for the statistics. Results MRPP showed a high agreement with radionuclide perfusion imaging. TROS was (2. 86 ± 2. 48 ) vs ( 6. 72 ± 2. 54) ( t = 3. 370, P < 0. 01 ), the peak time was ( 13.98 ±5.60) vs ( 12. 33 ± 3.63 ) s ( t = 3. 930, P < 0. 01 ), the peak value of main pulmonary blood flow was (60.39 ± 15. 17) vs (69.93±13.22) cm/s(t=2.930, P<0. 01) and mean flow velocity (11.68±5.46) vs ( 13.54 ± 4. 18 ) cm/s ( t = 2. 380, P < 0. 05 ) before and after anticoagulation or thrombolytic therapy. The flow rate per unit was (80. 57 ± 24. 87) vs ( 85.48 ± 11.81 ) ml/s ( t = 0. 86,P > 0. 05 ) . Conclusion MRPP shows a high agreement with radionuclide perfusion imaging and is a useful method for the diagnosis and follow-up of PE.