Primary research on direct multi-slice spiral CT venography in inferior vena cava
10.3760/cma.j.issn.1005-1201.2010.07.014
- VernacularTitle:多层螺旋CT下腔静脉直接成像的临床初步研究
- Author:
Peiyou GONG
;
Fengli LIU
;
Xianying MA
;
Li ZHAO
;
Liping WANG
;
Xuehua LI
;
Jian LI
- Publication Type:Journal Article
- Keywords:
Vena cava,inferior;
Tomography,X-ray computed
- From:
Chinese Journal of Radiology
2010;44(7):741-743
- CountryChina
- Language:Chinese
-
Abstract:
Objective To investigate the superiority of direct multi-slice spiral CT venography in inferior vena cava. Methods Twenty-eight patients performed MSCT venography in inferior vena cava, including 2 cases with both indirect and direct venography, 10 cases with indirect venography, 20 cases with direct venography through unilateral or bilateral lower extremity venous injection. The image quality and enhancement degree of the inferior vena cava were compared in double-blind method. Results Of 10 cases with indirect venography of inferior vena cava, 1 case was failed due to mild enhancement in inferior vena cava. Image quality was good in 2 cases, poor in 7 cases, no excellent case. Of 20 cases with direct venography of inferior vena cava, the enhancement degree was scored 1, 2 degree in 16, 4 cases respectively and no case was scored 3 degree, the image quality was excellent, good in 16, 4 cases and no case was bad. The success rate was 100%. Conclusion The image quality of direct MSCT venography in inferior vena cava is better than that of indirect method.