Role of multislice spiral CT in diagnosis of biliary complications after liver transplantation
10.3760/cma.j.issn.1007-8118.2010.07.002
- VernacularTitle:多层CT在肝移植术后胆道并发症中的诊断价值
- Author:
Xiaochun MENG
;
Kangshun ZHU
;
Yan ZOU
;
Junwei CHEN
;
Pengfei PANG
;
Hong SHAN
;
Shuhong YI
;
Junfeng ZHANG
;
Minqiang LU
- Publication Type:Journal Article
- Keywords:
Liver transplantation;
Biliary complication;
Tomography;
X-ray computed;
Cholangiography
- From:
Chinese Journal of Hepatobiliary Surgery
2010;16(7):484-487
- CountryChina
- Language:Chinese
-
Abstract:
Objective To analyze the role of multislice spiral CT in the diagnosis of biliary com-plications following liver transplantation. Methods Forty-four patients with biliary complications re-ceived tri-phase contrast-enhancement CT examination and cholangiography (CP) within one week af-ter the CT scanning. Using the results of CP as the standard, we investigated the efficacy of multislice spiral CT for each kind of biliary complication. All the analyses for bile duct were based on the images on the late portal venous phase and the reconstruction of images performed with multiplan reformat,Results CP depicted biliary strictures involved in extrahepatic bile duct in 23 cases (including the common bile duct and common hepatic duct), left or right hepatic duct in 24 and intrahepatic bile duct in 27. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of the CT examination were 91.3%, 83. 3% , 87. 8%, 87. 5% and 88. 2% for biliary stricture in extrahe-patic bile duct, 83. 3% , 88. 2%, 85. 4%, 90. 9% and 78. 9% for biliary stricture in left or right he-patic duct, 74.1%, 92.7%, 80.5%, 95.2% and 65.0%, for biliary stricture in intrahepatic bile duct, respectively. CT detected intrahepatic biloma in 4 cases and abscess in 2 but CP only detected biloma in 2 cases. The other 4 cases did not detected by CP because of severe biliary strictures which filled with biliary sludge. CP confirmed anastomotic bile leak in 3 cases. In these cases, CT only de-picted the fluid collection in hepatic hilum and abdominal cavity, none of the exact leak site could be detected. CP detected biliary sludge or stones in 33 cases. However, the sensitivity, specificity, accu-racy, positive predictive value and negative predictive value of the CT examination for biliary sludge or stones were 72.7%,100.0%,78.1%,100.0%and 47.6%,respectively.Meanwhile,in 1 patient with diffuse intrahepatic biliary strictures,active biliary bleeding was correctly detected by CT exami-nation and confirmed by hepatic arteriography.Conclusion Tri-phase contrast-enhancement CT exam-ination can be used as a general method for biliary complications after liver transplantation.Besides its benefits in biliary complications,it is of great value for depicting complications involved in hepatic pa-renchyma and acute biliary bleeding in the same examination.