Study on suceess rate of CT guided percutaneous pulmonary biopsy
10.3760/cma.j.issn.1008-6706.2010.18.012
- VernacularTitle:CT引导下经皮穿刺肺活检137例分析
- Author:
Honggang LIU
;
Xia CHEN
;
He MA
- Publication Type:Journal Article
- Keywords:
Biopsy,needle;
Tomograpluy,X-Ray,computed
- From:
Chinese Journal of Primary Medicine and Pharmacy
2010;17(18):2472-2473
- CountryChina
- Language:Chinese
-
Abstract:
Objective To discuss the technical factors of extrapleural locating in CT-guided percutaneous pulmonary biopsy. Methods 137 cases undervent CT-guided percutaneous pulmonary biopsy were retrospectively analyzed. The technical methods of operation,points and points for attention were analyzed. Results In this group the success rate of data manipulation was 98.5%. No serious complications of the operation were occured. Scan completed within 40-story biopsy rate was 71.5%. The needle into the target rate for the first time was 93.4%. Conclusion CT-guided biopsy could increase the detection rate of difficult lesions and patient satisfaction rate paying attention on thinking and practice in the preoperative preparation and intraoperative specific operations.