Application of ultrasound-guided Mammotome in the diagnosis and treatment of breast neoplasms
10.3760/cma.j.issn.1008-6315.2010.11.038
- VernacularTitle:超声引导下Mammotome微创旋切技术在乳腺肿块诊治中的应用
- Author:
Jian SUN
;
Ang DING
;
Taiming SUN
;
Maoli WANG
;
Yuchun JIN
;
Hongliang CHEN
;
Yongxi YUAN
- Publication Type:Journal Article
- Keywords:
Breast neoplasm;
Minimally invasive surgery;
Ultrasound-guided Mammotome
- From:
Clinical Medicine of China
2010;26(11):1219-1221
- CountryChina
- Language:Chinese
-
Abstract:
Objective To summarize and explore the clinical value of Mammotome technology in the diagnosis and treatment of breast neoplasms. Methods Nine hundred and eighty-seven breast neoplasms of 710patients were biopsied and excised with the aid of ultrasound-guided Mammotome system. The malignant neoplasms,according to the histological report,were radically removed during the operation without delay. All patients enrolled into the study were followed up closely on the complcations and satisfaction degree. Results All the operations except one were successful and got the sufficient specimen to perform the pathological examination,the biopsy achievement rate was 99. 8% . Both the sensitivity and specificity of the diagnosis were 100% in 16 breast tumors. Complete resection rate was 99%. The incision length was about 3 mm,showing good cosmetic outcome. Complcations were mild,mainly composed of haematoma and ecchymosis. The patients' general satisfactory rate was 93%. Conclusions This technique can help achieve biopsy of breast neplasm and excision of benign lesions at the same time with cosmetic result Further attention should be paid to reduce the lesion residue and hemorrhagic complications.