Influencing factors on the detection rate of duodenal papilla by capsule endoscopy
- VernacularTitle:胶囊内镜对十二指肠乳头的检出率及其影响因素分析
- Author:
Yunjie GAO
;
Zhizheng GE
;
Xiaobo LI
;
Jun DAI
;
Wei WEI
- Publication Type:Journal Article
- Keywords:
Capsule endoscopy;
Duodend papilla;
Detection rate
- From:
Chinese Journal of Digestive Endoscopy
2008;25(4):169-172
- CountryChina
- Language:Chinese
-
Abstract:
Objective To determine the detection rate of duodenal papilla and the diagnostic rate of small bowel diseases by capsule endoscopy(CE)and its possible influencing factors.Methods A total of 369 cases with suspected small bowel disease who had undergone CE were retrospectively reviewed. The de- tection rate of duodenal papilla and that of small bowel disease were calculated respectively. The detection rate of duodenal papilla in another 369 patients having received gastroscopy was also counted in order to findout the miss detection rate of forward-viewing endoscopy. The CE findings were reviewed at the rate of 1 im-age and 15 images per second by hand-motion respectively. The detection rate of duodenal papilla was calcu-lated,and the number of frames showing duodenal papilla was counted. Differences of detection rate of duo-denal papilla were also analyzed by different age and gender groups. In addition,the potential difference in detection rate of duodenal papilla between different bowel preparations before CE of two different reviewing approaches was also investigated respectively. Results The miss detection rate of duodenal papilla with for-ward-viewing gastroscopy was 22. 0%. The detection rate of duodenal papilla reviewed at the rate of 1 image by hand-motion,where less frames were needed to visualize duodenal papilla(3. 7vs7. 0),was significantly higher than that at the rate of 15 images per second(32. 2%vs13. 6%,P=0. 001). The diagnostic rate of small bowel diseases was also significantly higher than that of duodenal papilla by CE(67. 2%vs32. 2%,P=0. 000). Age and gender were not significantly correlated with the detection rate of duodenal papilla. No significant correlation was found between various kinds of bowel preparation before CE at different viewing rate and the detection rate of duodenal papilla. Conclusion It iS relatively difficult to identify duodenal pa- pilla by CE,as they are peculiarly positioned in anatomy,so the detection of duodenal papilla does not nec- essarily represent the detection rate of small bowel diseases. The major factors that influencing the detection of duodenal papilla by CE include local anatomy,viewing rate and technical limitations of CE.