Valve replacement plus reconstruction of the annulus
10.3760/cma.j.issn.1001-4497.2011.02.009
- VernacularTitle:瓣环结构重建的瓣膜置换手术
- Author:
Lin HAN
;
Zhiyun XU
;
Liangjian ZOU
;
Zhinong WANG
;
Jun WANG
;
Guanxin ZHANG
- Publication Type:Journal Article
- Keywords:
Heart valve diseases;
Heart valve prosthesis implantation;
Endocarditis;
Aortic stenosis
- From:
Chinese Journal of Thoracic and Cardiovascular Surgery
2011;27(2):90-92
- CountryChina
- Language:Chinese
-
Abstract:
Objective To investigate the surgical technique and clinical outcomes of reconstruction of the annulus and the intervalvular fibrous body during valve replacements. Methods Fifty-nine patients underwent reconstruction of the annulus or the intervalvular fibrous body during the valve replacement. Indications for the operation were small aortic annulus which may cause patient/prosthesis mismatch in 43, active infective endocarditis with the abscess in the periannulus tissue in 13, extensive calcification of the aortic annulus in 2 and an active bleeding complication of the aortic root after aortic and mitral valve replacement in 1. The reconstruction was done with fresh autologous pericardium. Results The aortic clamping time in reconstruction of the intervalvular fibrous body with double valve replacement was longer than that of the regular double valve replacement. Four patients died in the perioperative period, giving an overall in- hospital mortality of 6.7%. Postoperative complication were: re-sternotomy for bleeding in 2, Ⅲ degree A-V block in 2, respiratory dysfunction in 2, and acute renal failure in 2. Patients were followed up for 6 months by echocardiography study, and no periannular leakage was found. Conclusion Reconstruction of the annulus is an effective technique for patients with a small aortic annulus, extensive calcification of the interventricular fibrous body and active infective endocarditis with abscess. Although the operative procedure is challenging and taking more time, the technique is safe and reproducible.