A Case of Urgent Thoracic Endovascular Aortic Repair with the Double-Chimney Graft Technique for a Ruptured Thoracic Aortic Aneurysm
10.4326/jjcvs.44.228
- VernacularTitle:破裂性胸部大動脈瘤に対して chimney technique を用いた胸部ステントグラフト内挿術と二期的コイル塞栓術で救命し得た1例
- Author:
Kota Shukuzawa
;
Naoki Toya
;
Yasutake Momokawa
;
Soichiro Fukushima
;
Tadashi Akiba
;
Takao Ohki
- Publication Type:Journal Article
- Keywords:
ruptured thoracic aortic aneurysm;
TEVAR;
chimney technique;
endoleak;
coil embolization
- From:Japanese Journal of Cardiovascular Surgery
2015;44(4):228-231
- CountryJapan
- Language:Japanese
-
Abstract:
A 73-year-old woman suffered from ruptured aortic arch aneurysm into mediastinum. The patient was treated by thoracic endovascular aortic repair with the double-chimney graft technique. Three days later, computed tomography (CT) revealed type 1a endoleak (EL) between the chimney grafts. Ten days later, the patient was treated by coil embolization of the aneurysm from the left subclavian artery. The patient recovered, and was without aortic aneurysm events during six months of follow up.