"Oketsu" and Hemorheological Changes-Examination by Micro Channel Array Flow Analyzer-(the first report)
10.3937/kampomed.55.645
- VernacularTitle:お血と血液流動性変化―Micro Channel Array Flow Analyzer測定による検討―(第I報)
- Author:
Yuzo HORIBE
;
Syogo ISHINO
;
Naoko HISAMITSU
;
Thein LAIN
;
Shintaro ISHIKAWA
;
Takao SATO
;
Tadashi HISAMITSU
- Publication Type:Journal Article
- Keywords:
oketsu;
blood fluidity;
MC-FAN
- From:Kampo Medicine
2004;55(5):645-648
- CountryJapan
- Language:Japanese
-
Abstract:
Scientific elucidation of “oketsu (blood stasis)” states is very important to understanding the diagnostic methods of oriental medicine. We investigated the correlation of blood fluidity to oketsu states, by micro channel array flow analyzer (MC-FAN). Twenty-seven female patients were divided into three groups: a non-oketsu group, a mildly affected group, and a severely affected group according to the diagnostic criteria of their oketsu syndrome. Immediately after collecting their venous blood, whole blood passage time was measured by MC-FAN. And we compared and investigated the correlation with degree of oketsu state, diagnostic criteria and changes of whole blood passage time after the administration of ku-oketsu drugs. As a result, whole-blood passage time of the mildly affected group and the severely affected group were significantly longer than that of the non-oketsu group, while the [an] improvement of blood fluidity was observed after medication. This study confirms that reduced blood fluidity is seen using MC-FAN in oketsu states, and that ku-oketsu drugs are able to improve these states.