A Case of Obturator Foramen Bypass for Infected Femoral Artery after Use of an Arterial Closure Device
10.4326/jjcvs.32.370
- VernacularTitle:カテーテル検査後大腿動脈感染に対する閉鎖孔バイパスの経験
- Author:
Shin Uchikawa
;
Noboru Murata
;
Kazuhide Hayashi
- Publication Type:Journal Article
- From:Japanese Journal of Cardiovascular Surgery
2003;32(6):370-373
- CountryJapan
- Language:Japanese
-
Abstract:
A 52-year-old man with a 10-year history of severe diabetes was referred to our hospital with hemorrhage from a methicillin-resistant Staphylococcus aureus-infected femoral artery following the use of an arterial closure device (Prostar XL: Perclosure, Co., Ltd., Redwood, CA, USA). At surgery, the common femoral artery showed a circular area of disintegration, 9mm in diameter, due to massive infection. One month after femoral angioplasty with a saphenous vein patch, re-hemorrhage occurred as a result of uncontrollable infection. Next, an obturator foramen (OF) bypass was performed and the infected femoral artery was removed. Two months after OF bypass, the wound healed and the patient was well. We conclude that OF bypass is a satisfactory method of treatment for compromised patients with an infected femoral artery.