One-Stage Repair for Infants with Complex Coarctation without Homologous Blood Transfusion.
10.4326/jjcvs.29.118
- VernacularTitle:大動脈縮窄複合の乳児に対する,同種血非使用一期的修復術
- Author:
Yuko Suzuki
;
Yukihiro Takahashi
;
Toshio Kikuchi
;
Nobuyuki Kobayashi
;
Eisaku Nakamura
- Publication Type:Journal Article
- From:Japanese Journal of Cardiovascular Surgery
2000;29(2):118-121
- CountryJapan
- Language:Japanese
-
Abstract:
We successfully performed one-stage definitive repair for 3 infants weighing 4.2, 6.1 and 5.2kg with complex coarctation without homologous blood transfusion. The priming volume of the bypass circuits was 195ml, and their lower hematocrit values during cardiopulmonary bypass were 15, 16 and 13%, respectively. In order to diminish the aortic cross clamp time, the aortic arch was repaired with the heart beating, using isolated cerebral and myocardial perfusion methods. The base excess in each patient decreased to -9.4, -8.0 and -4.9mEq/l during the rewarming phase, however, their postoperative hemodynamic and respiratory conditions were satisfactory. They have grown without any sequelae for at least 2 months.