Eliminating Homologous Blood Transfusion Using a Cell Saver during Abdominal Aortic Aneurysm Repair.
10.4326/jjcvs.25.86
- VernacularTitle:腹部大動脈りゅう手術における術中自己血回収輸血装置の有用性
- Author:
Takehisa Nojima
;
Tatsuo Magara
;
Atsushi Katsura
;
Tadao Nishikawa
;
Shoji Watarida
;
Masahiko Onoe
;
Takaaki Sugita
;
Kazuhiko Katsuyama
;
Atsumi Mori
;
Ryuzaburo Yasuda
- Publication Type:Journal Article
- Keywords:
Cell Saver
- From:Japanese Journal of Cardiovascular Surgery
1996;25(2):86-89
- CountryJapan
- Language:Japanese
-
Abstract:
The purpose of this study was to determine the effect of intraoperative autologous blood salvage during elective abdominal aortic aneurysm repair with Cell Saver 4 (Heamonetics Inc.). Fifty patients prospectively received intraoperative autologous transfusion (Group CS; n=50, 1991-94) and 25 received no intraoperative autologous transfusion (Group NCS; n=25, 1983-91). Only 7 patients in Group NCS received no homologous blood (28%), while 43 in Group CS received autologous blood transfusion (86%). There was no difference between the groups with respect to postoperative platelets counts or serum concentrations of total protein, albumin, BUN and LDH. We conclude that the use of the Cell Saver 4 reduces perioperative homologous blood during elective aortic aneurysm repair.