Late (3years) antomical patency of a No-flow internal mammary artery bypass graft.
10.4326/jjcvs.20.656
- VernacularTitle:冠動脈バイパス術後3年目の造影検査で内胸動脈グラフトが“no flow Patency”を示した一症例
- Author:
Noriyoshi SAWABATA
;
Soichiro KITAMURA
;
Toshio SEKI
;
Ryuichi MORITA
;
Kanji KAWACHI
;
Tetuji KAWATA
;
Junichi HASEGAWA
- Publication Type:Journal Article
- From:Japanese Journal of Cardiovascular Surgery
1991;20(4):656-659
- CountryJapan
- Language:Japanese
-
Abstract:
The left IMA graft to the LAD showed a string sign with no antegrade flow in an asymptomatic 67-year-old man 3 years after the operation. The LAD lesion had regressed from 95% stenosis to less than 50% during this period. Exercise electrocardiographic and thallium 201 myocardial scintigraphic examinations revealed no ischemia in the LAD region. When the LAD was temporarily occluded by a PICA balloon, the anterograde flow from the IMA to the LAD could be demonstrated by angiography. The IMA graft in no flow situation has maintained anatomical patency for 3 years after the operation.