A Case of Repeated Pacemaker Implantation to Treat Pacemaker Dermatitis
10.4326/jjcvs.40.140
- VernacularTitle:ペースメーカーに対する金属アレルギーによる難治性皮膚潰瘍症例に対し polytetrafluoroethylene シート被覆心筋リードを留置した1例
- Author:
Yuki Seto
;
Hiroyuki Satokawa
;
Yoichi Sato
;
Shinya Takase
;
Hiroki Wakamatsu
;
Hiroyuki Kurosawa
;
Eitoshi Tsuboi
;
Takashi Igarashi
;
Akihiro Yamamoto
;
Hitoshi Yokoyama
- Publication Type:Journal Article
- Keywords:
pacemaker dermatitis;
polytetrafluoroethylene;
contact sensitivity
- From:Japanese Journal of Cardiovascular Surgery
2011;40(3):140-143
- CountryJapan
- Language:Japanese
-
Abstract:
An 84-year-old man, who had been given a diagnosis of advanced aortoventricular block 2 years previously, underwent implantation of a pacemaker (PM) through the left subclavian vein. However, 7 months later a skin ulcer developed at the implantation site, but without any evidence of bacterial infection. Therefore, a PTFE-covered PM battery was reimplanted at the same site. Three months later, the skin ulcer recurred and he received a third implantation in the right side. However, another skin ulcer with infection developed in the right side. He was then transferred to our hospital for another PM reimplantation. We covered the battery and the entire lead with PTFE, then placed the PM lead directly into the cardiac muscle, and implanted the PM battery below the rectal muscle under general anesthesia. A patch test 4 months later revealed a positive reaction to nickel and silicon. Finally, we diagnosed pacemaker dermatitis. The patient has remained free of skin ulcers for over 1 year.