Open reduction and internal fixation for displaced supracondylar fractures of the humerus in children with crossed K-wires via lateral approach.
- Author:
Shahid HUSSAIN
1
;
Manzoor AHMAD
;
Tufail MUZAFFAR
Author Information
- Publication Type:Journal Article
- MeSH: Bone Wires; Child; Female; Fracture Fixation, Internal; methods; Humans; Humeral Fractures; surgery; Male; Prospective Studies
- From: Chinese Journal of Traumatology 2014;17(3):130-135
- CountryChina
- Language:English
-
Abstract:
OBJECTIVETo assess the therapeutic results of open reduction and internal fixation with crossed K-wires via lateral approach for displaced supracondylar fractures of the humerus in children.
METHODSWe prospectively followed 52 children who presented with Gartland type 3 displaced supracondylar fractures of the humerus and were managed by open reduction and internal fixation with crossed K-wires via lateral approach.There were 37 male and 15 female patients; average age was 7.39 years. The most common mechanism of trauma was fall while playing (n=23), followed by fall from height (n=20), road traffic accidents (n=5) and fall from standing height (n=2). In 2 cases, mode of injury was not available. The mean follow-up was 12 months and patients were assessed according to Flynn's criteria.
RESULTSLateral approach provided an excellent view of the lateral column between two nervous planes and enabled an anatomical reduction in all cases. Immobilizing the elbow at 90 degrees or more of flexion was not needed after cross K-wire fixation. Majority of patients regained full range of motion within 6 weeks of pin removal. Two patients had postoperative ulnar nerve injuries that resolved after pin removal. The common late complication of cubitus varus was not seen in any patient. Delayed presentation to the emergency department, repeated manipulations by bone setters and massage with edible oil were responsible for stiffness in 5 patients. Superficial pin tract infection was noted in 5 patients that resolved with dressings and antibiotics. No deep infection occurred. A detailed clinical examination and radiographic analysis was done at final follow-up. They included measurement of carrying angle and range of movements of both operated and normal sides, and radiographs of both upper limbs for comparison. According to Flynn's criteria, 90.4% patients showed satisfactory results.
CONCLUSIONLateral approach for open reduction and internal fixation of the widely-displaced supracondylar fracture of the humerus is safe and straightforward, ensuring anatomical reduction and excellent function. The approach is easy and familiar to most orthopedic surgeons in our setup.