Root resection by Er:YAG laser: a scanning electron microscope study.
- Author:
Xiao-yi ZHAO
1
;
Shi-ming WANG
;
Cheng-fei ZHANG
Author Information
- Publication Type:Journal Article
- MeSH: Dentin; Incisor; Lasers, Solid-State; Microscopy, Electron, Scanning; Smear Layer
- From: West China Journal of Stomatology 2010;28(5):526-528
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVETo compare the difference of the surface of root resection by Er:YAG laser, ultrasonic or high-speed handpiece with scanning electron microscope (SEM), and to evaluate the possibility of using Er:YAG laser on the root resection in clinical application.
METHODSThirty maxillary central incisors were divided into three groups (Er:YAG laser group, ultrasonic group, high-speed handpiece group), and the root resection were made at root tip 3 mm with Er:YAG laser, ultrasonic instrument or long needle diamond bur according to grouping. The surface of the root resection by SEM in the aspects of debris, smear layer, opened dentinal tubules, cracks and ablation characteristics were compared.
RESULTSThe examination revealed that Er:YAG laser group and ultrasonic group had no or little debris and smear layer and with opened dentinal tubules. High-speed handpiece group had great amount of debris and smear layer and without opened dentinal tubules. Cracks were observed in ultrasonic group and high-speed handpiece group, no in Er:YAG laser group. There were ablation characteristics in ultrasonic group and high-speed handpiece group, but no in Er:YAG laser group.
CONCLUSIONFrom the morphological aspect, Er:YAG laser has much more advantage than ultrasonic instrument and diamond bur for the root resection.