Three dimensional finite element analysis of biomechanical distribution of dental implants with immediate loading.
- Author:
Xue-lian HAN
1
;
Zong-wei LIU
;
Yan-tao LI
Author Information
- Publication Type:Journal Article
- MeSH: Dental Implants; Dental Stress Analysis; Female; Finite Element Analysis; Humans; Mandible; Stress, Mechanical
- From: West China Journal of Stomatology 2011;29(2):121-124
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVETo analyze the stress distribution of bone around the dental implants with lateral immediate loading of different angles by three dimensional finite element.
METHODSAn adult edentulous mandible was adopted for CT scanning. The CT image was imported to universal surgical integration system to establish a mandible three dimensional mesh model. The real shape of standard thread implant was simulated and the finite element model of mandible with dental implants for immediate loading was established. The models were immediately loaded with 150 N through the angle of 0 degrees, 10 degrees, 20 degrees, 30 degrees. The ANSYS 10.0 was used to analyze the Von Mises stress on the bone around dental implants.
RESULTSThe accurate finite element model of mandible with dental implants for immediate loading was successfully established. The three dimensional finite element analytical results showed: Under axial load, the Von Mises stress of bone contact surface concentrated on the cortical bone of the implant cervix. The strain distribution was even, and centralized at the cortical bone of the implant cervix, cancellous bone of implant bottom and thread contact area. Under different lateral angle load, the Von Mises stress of bone contact surface also concentrated on the cortical bone of the implant cervix, but the maximum value was 4 times of the vertical loading, the strain distributed unevenly, mainly concentrated on the cortical bone of the implant cervix. With the load angle increased, the stress and the strain value also increased.
CONCLUSIONWhen an axial force was immediately loaded, the stress value and the strain concentration value of bone interface around the dental implants are not apparently concentrated, the stress is distributed well. While a lateral force is loaded, the stress values and the strain concentration values of bone interface around the dental implants apparently increase and the strain are distributed unevenly.