Diagnostic value of 3D-indirect magnetic resonance arthrography in detecting meniscal tears of the knees.
- Author:
Liao WANG
;
Ru-Qing YE
;
Kai JIANG
;
Yuan-Hua WU
;
Sheng-Zan WU
;
Sheng-De DENG
;
Jian-Hua WANG
- Publication Type:Journal Article
- MeSH: Adult; Aged; Arthrography; methods; Female; Humans; Imaging, Three-Dimensional; methods; Knee Injuries; diagnosis; Magnetic Resonance Imaging; methods; Male; Middle Aged; Tibial Meniscus Injuries
- From: China Journal of Orthopaedics and Traumatology 2015;28(3):282-285
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVETo explore the diagnostic value of 3D-indirectmagnetic resonance (MR) arthrography in detecting meniscustears of the knees.
METHODSForm January 2013 to January 2014, routine plain MR of the knees followed by the 3D-indirect MR arthrography was performed in 42 patients with suspected meniscal tears clinically. There were 31 males and 11 females, with an average age of 38.4 years old (ranged, 21 to 67 years old). The duration of the course ranged from 2 h to 15 d. The clinical symptom was knee pain. All the patients got subsequently arthroscopic examination or operation. The sensitivity and specificity of routine plain MR and 3D-indirect MR arthrography were compared based on the results of arthroscopic examination or operation.
RESULTSThe signal intensity in the area of meniscal tears on image of 3D-indirect MR arthrography was obviously higher than that of routine plain MR. The sensitivity of 3D-indirect MR arthrography was 85.79% (87/102), while the routine plain MR was 52.94% (54/102), and the specificity improved from 67.78%(61/90) to 86.67%(78/90). The difference was statistically significant (χ2 = 25.90, P < 0.01; χ2 = 9.13, P < 0.01).
CONCLUSIONIn comparison with the routine plain MR findings, 3D-indirect MR arthrography demonstrates meniscus tears of the knee with the better sensitivity and specificity.