Relationship between nasal discharge eosinophils and responses to treatment of inhaled glucocorticosteroid in patients with allergic rhinitis
10.3760/cma.j.issn.1673-0860.2009.03.007
- VernacularTitle:变应性鼻炎患者鼻分泌物中嗜酸粒细胞计数与鼻用糖皮质激素治疗反应的关系
- Author:
Hong LUO
1
;
Neng-Bing YAN
;
Jun LIU
;
Ze-Zhang TAO
;
Ping-Fan ZENG
;
Yan JIANG
;
Ye YU
;
Peng-Ju WANG
;
Wei-Jia KONG
Author Information
1. 华中科技大学同济医学院附属襄樊市中心医院
- Keywords:
Rhinitis,allergic,perennial;
Glucocorticoids;
Eosinophils;
Eesinophil cationicprotein
- From:
Chinese Journal of Otorhinolaryngology Head and Neck Surgery
2009;44(3):209-213
- CountryChina
- Language:Chinese
-
Abstract:
Objective To evaluate the treatment responses of persistent allergic rhinitis with and without nasal discharge eosinophilia (EOS) to inhaled glucocorticosteroid (CS), and therefore to verify whether low nasal discharge eosinophils predict poor response to treatment with CS. Methods Forty-two symptomatic allergic rhinitis patients, who had not received CS therapy in three months preceding the study, were examined before and 2 month, 4 months and 6 months after treatment with CS. At each visit, all patients underwent symptom scoring and physical sign scoring. The level of eosinophil cationic protein (ECP) in the nasal discharge supernatants was measured by radioimmunoassay. The patients were divided into 2 groups according to nasal discharge EOS percentages, an EOS group(group A , EOS≥0.03) and a non-EOS group (group B, EOS < 0.03). The response to CS therapy (as measured by symptom and physical sign scores) and the changes of nasal discharge measurements were compared between the 2 groups. Results In the group A, the baseline EOS [0.086(0.065;0.176)] and ECP level [(326 ± 145)μg/L] were significantly higher than those of the group B [0.016(0.005;0.022)] and ECP level (154±58)μg/L], respectively, t =4.40, 3.33, both, all P <0.01. After 2 month and 6 months CS therapy, the nasal discharge EOS, ECP pred were 0.038(0.006;0.070), 0.019(0.010;0.060), (175 ± 122)μg/L, (175 ±153)μg/L, respectively in the EOS group, which were significantly different as compared to baseline values (F = 6.73, 7.38, respectively, all P < 0.05). But in the non- EOS group, the nasal discharge EOS ECP pred were 0.014(0.004;0.032),0.015(0.000;0.026),(118±60)μg/L, (112±60)μg/L, respectively at 2 and 6 months, which showed that the the nasal discharge EOS pred and the symptom and physical sign scores improved did not change (F = 0.82, P > 0.05), but the ECP level improved (F = 3.78, P <0.05). and the average daily dose of CS wear not different between the two groups at any visits. Conclusions In persistent allergic rhinitis with low nasal discharge EOS, CS therapy for 6 months failed to improve symptom and physical sign.