Analysis of apposition on differently treated implant surface at early stage of implantation.
- Author:
Fu-ming HE
1
;
Song CHEN
;
Shan-shan ZHAO
Author Information
- Publication Type:Journal Article
- MeSH: Animals; Dental Implantation; Dental Implants; Dental Materials; chemistry; Dental Prosthesis Design; Hydrogen Peroxide; chemistry; Osseointegration; physiology; Osteogenesis; physiology; Rabbits; Surface Properties; Tibia; surgery; ultrastructure; Titanium; chemistry
- From: Journal of Zhejiang University. Medical sciences 2006;35(5):472-478
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVETo compare the surface apposition and the bone response at early period of implantation in two differently treated implants.
METHODSThe implants were subject to double acid-etched-H2O2/HCl-heat treatment and double acid-etching treatment, and then randomly implanted into the tibia of rabbits. After 2, 4, 8 weeks of follow up, the bone specimens containing implants were prepared and examined by a field emission SEM and EDX.
RESULTA layer rich with calcium and phosphorus was clearly demonstrated on the implants surface of both groups after 2 weeks of implantation, but it was mostly disappeared after 4 weeks. There were large amounts of osteoblasts cells on double acid-etched-H2O2/HCl-heat treated implants surface indicating the initiation of osteogenesis. After 8 weeks of implantation some new bones were attached on the implants surface in both groups, more bones attached were shown on double acid-etched- H2O2/HCl-heat treated implants surface.
CONCLUSIONA calcium and phosphorus-rich layer was formed on the implants surface of both groups at early period of implantation.