Intravascular ultrasound assessment of chitosan/heparin layer-by-layer self assembly coating stent on late stent malappoisition and vessel remodeling in porcine model
10.3760/cma.j.issn.0253-3758.2012.07.006
- VernacularTitle:血管内超声评价壳聚糖/肝素层层自组装涂层支架贴壁情况及对猪冠状动脉重构的影响
- Author:
Li SHEN
1
;
Yi-Zhe WU
;
Feng ZHANG
;
Ai-Jun SUN
;
Wei ZHONG
;
Ju-Ying QIAN
;
Jun-Bo GE
Author Information
1. 复旦大学附属中山医院
- Keywords:
Stents;
Ultrasonography,interventional;
Coronary restenosis
- From:
Chinese Journal of Cardiology
2012;40(7):569-574
- CountryChina
- Language:Chinese
-
Abstract:
Objective To investigate late stent malapposition or vessel remodeling post chitosan/heparin layer-by-layer self assembly coating stent (LBL) implantation in porcine.Methods A total of 32 stents [ bare metal stent ( BMS,n =9),sirolimus-eluting stent ( SES,n =11 ) and LBL ( n =12 ) ] were implanted into coronary arteries of 16 porcine.Intravascular ultrasound (IVUS) was performed immediately after stenting and at 1 month after stenting to measure vessel area (VA),stent area (SA) and lumen area (LA).Neointima area (NA) was measured at 1 month post stenting by IVUS to detect signs of stent malapposition and to determine remodeling index (RI). Histopathology was performed at 1 month post stenting to observe vessel wall structure and stent malapposition status.Results No sign of stent malapposition was detected,VA and SA/LA were similar among groups immediately after stent implantation.At 1 month follow-up,none of three groups showed stent malapposition.VA,SA,NA and LA were ( 7.30 ±0.77),(6.83 ±0.76),(1.40 ±0.96) and (5.43 ±0.88)mm2 in LBL group,(7.13 ±0.69),(6.63 ±0.71 ),(0.28 ±0.35) and (6.34 ±0.89)mm2 in SES group,(7.48 ±0.70),(7.00 ±0.52),(2.69 ±1.58) and (4.31 ± 1.28)mm2 in BMS group.VA and SA were similar among groups ( all P >0.05 ).LA in LBL group was smaller than SES group ( P < 0.01 ) and significantly larger than in BMS group ( P <0.05 ).NA in LBL group was larger than SES group (P <0.01 ) and significantly smaller than in BMS group (P < 0.05 ).RI in LBL,SES and BMS groups was 0.95 ± 0.07,1.02 ± 0.04 and 0.98 ± 0.04 ( P >0.05).Conclusions There is no late stent malapposition or abnormal remodeling post LBL,SES and BMS implantation up to 1 month in this porcine model.LA in LBL group is smaller than SES group and larger than BMS group at 1 month after implantation in this porcine model.