Determination of mandelic acid and phenylglyoxylic acid in urine by reagent-free ion chromatography.
- Author:
Guojian SHAO
;
Juan YU
;
Danqing WU
- Publication Type:Journal Article
- MeSH: Chromatography, Ion Exchange; Glyoxylates; urine; Humans; Mandelic Acids; urine; Styrene
- From: Chinese Journal of Industrial Hygiene and Occupational Diseases 2015;33(4):301-303
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVETo develop a method for determination of mandelic acid (MA) and phenylglyoxylic acid (PGA) in urine by reagent-free ion chromatography.
METHODSIon chromatography was performed on an AS19 column with a gradient elution solution containing 10-35 mmoL/L KOH at a flow rate of 1.00 ml/min, and MA and PGA were detected at ultraviolet wavelengths of 225 nm and 254 nm, respectively. The samples were diluted 10 times with purified water, then purified on a silver column to remove high concentrations of chloride ion, and injected after being filtered through a 0.2-µm m filter membrane.
RESULTSThe recoveries of standard addition of MA and PGA were 96.5% and 99.3%, respectively, with both relative standard deviations less than 5.0%. Good linear relationships were noted in the range of 1.0-100.0 mg/L for both MA and PGA (r >0.9995). The detection limits of MA and PGA were 0.02 mg/L and 0.05 mg/L, respectively; the minimum detectable concentrations of MA and PGA were 0.2 mg/L and 0.5 mg/L (when the sampling amount was 5.0 ml and diluted to 50.0 ml with water, and the injection volume was 300 µL).
CONCLUSIONSThis method is fast, convenient, and highly sensitive and selective. It can be used for the analysis of MA and PGA in the urine of styrene-exposed workers.