Application of vacuum-assisted venous drainage technology in minimally invasive cardiac surgery.
- Author:
Shi CHENG
1
;
Tianxiang GU
;
Zongyi XIU
;
Limin WU
;
Rui GAO
;
Ya GAO
Author Information
- Publication Type:Journal Article
- MeSH: Adolescent; Adult; Aged; Cardiac Surgical Procedures; methods; Drainage; methods; Female; Humans; Male; Middle Aged; Minimally Invasive Surgical Procedures; methods; Vacuum; Veins; Young Adult
- From: Chinese Journal of Medical Instrumentation 2011;35(6):428-430
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVETo summarize the method and experience of cardiopulmonary bypass (CPB) with vacuum-assisted venous drainage technology (VAVD) in the minimally invasive cardiac surgery (MICS).
METHODS35 cases of patients undergoing MICS were achieved femoral arterial cannula and femoral venous cannula. During the course of the CPB, we used the VAVD technology. At the same time, we selected 35 cases as control group.The time of the CPB, mechanical ventilation and ICU, and the amount of the urine, blood products, and chest drainage were recorded.
RESULTSThe time of mechanical ventilation and ICU staying, the volume of the blood products and the volume drainage within 48 h postoperatively in the MICS group were significantly shorter and less than that in control group (P < 0.05).
CONCLUSIONThe use of VAVD in the MICS can increase the vena cava drainage effectively, and ensure the surgery safe and successful.