Finite element stress analysis of all-ceramic crown of the upper central incisor in differential thickness.
- Author:
Jian HU
1
;
Feimin ZHANG
;
Ning DAI
;
Shuanggao LI
;
Weiping GU
;
Junchi MA
Author Information
- Publication Type:Journal Article
- MeSH: Ceramics; Crowns; Dental Porcelain; Dental Stress Analysis; Finite Element Analysis; Humans; Incisor; Tensile Strength
- From: West China Journal of Stomatology 2012;30(4):356-359
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVETo investigate the stress distributions under load in an all-ceramic crown of the upper central incisor in differential thickness.
METHODSThe 3-dimensional finite element model of all-ceramic crown of the upper central incisor in differential thickness was applied with differential loads (100, 150, 200 N). The stress values and distributions of all-ceramic crown were calculated and expressed.
RESULTSThe tendency of stress distributions in all-ceramic crown of differential thickness and loads was similar. The maximal stress intensity value was located in the loading site and the cervical region. As the thickness of all-ceramic crown increased, the stress concentration reduced. When the load increased, the stress values increased, especially in the loading site and the cervical region.
CONCLUSIONThe increasing of the thickness of all-ceramic crown will decrease stress concentration. Because stress concentration is mainly in cervical region and loading site, these regions should be cared in fabrication of all-ceramic crown.