Transradial artery intervention: an alternative approach for renal artery stent implantation?
- Author:
Jian-fang LUO
1
;
Hui-yong WANG
;
Wen-hui HUANG
;
Yuan LIU
;
Guang LI
;
Ying-ling ZHOU
;
Ji-yan CHEN
Author Information
- Publication Type:Journal Article
- MeSH: Aged; Angiography; Angioplasty; methods; Female; Humans; Male; Middle Aged; Renal Artery; diagnostic imaging; Renal Artery Obstruction; diagnostic imaging; therapy
- From: Chinese Medical Journal 2012;125(18):3340-3343
- CountryChina
- Language:English
-
Abstract:
BACKGROUNDTransfemoral artery access is the main approach for the interventional treatment of renal artery stenosis (RAS). This study aimed to investigate the technical feasibility of a transradial interventional (TRI) treatment of renal artery stenosis.
METHODSA series of 23 patients who underwent transradial renal artery stenting from October 2010 to October 2011 were studied. Radial sheath system (Terumo, Japan) was used to get access to the radial artery. Radial tourniquet (Terumo) was used to stop bleeding. A 5Fr MPA (COOK, USA) was used to perform selective renal arteriography. Percutaneous renal artery stent systems were used to perform renal artery stenting.
RESULTSRenal artery angiography showed that 15 patients had unilateral renal artery stenosis and eight patients had bilateral renal artery stenosis. The descending aorta could not be catheterized in one patient because of the type III aortic arch. Twenty-two patients successfully underwent transradial renal artery angiography and the technical success rate was 95.7%. There was no puncture site hematoma or pseudoaneurysm. Mean procedure time was (38.4 ± 7.2) minutes, the mean amount of contrast agent used was (93.2 ± 6.3) ml, and the mean postprocedure bleeding time was (3.2 ± 1.9) minutes.
CONCLUSIONTransradial renal artery intervention is technically reliable with less invasion, rapid recovery, fewer complications and may become an alternative intervention approach for the treatment of renal artery stenosis.