Predictors of left atrial appendage stunning after electrical cardioversion of non-valvular atrial fibrillation.
- Author:
Shaning YANG
1
;
Congxin HUANG
;
Xiaojun HU
;
Lijun JIN
;
Fengzhu LI
;
Shuixian PENG
Author Information
- Publication Type:Journal Article
- MeSH: Aged; Aged, 80 and over; Atrial Appendage; physiopathology; Atrial Fibrillation; physiopathology; therapy; Electric Countershock; adverse effects; Female; Humans; Male; Middle Aged
- From: Chinese Medical Journal 2003;116(10):1445-1450
- CountryChina
- Language:English
-
Abstract:
OBJECTIVETo identify predictors of left atrial appendage stunning after the use of electrical cardioversion to restore sinus rhythm in patients with non-valvular atrial fibrillation.
METHODSA total of 68 consecutive patients (45 men, 23 women, 60.5 +/- 8.7 years of age) with non-valvular atrial fibrillation undergoing electrical cardioversion were enlisted in this study. Clinical and echocardiographic variables were analyzed by univariate regression and multivariate logistic regression to investigate the relationship between occurrences of left atrial appendage stunning and these factors.
RESULTSUnivariate analysis revealed that, in comparing patients without and with left atrial appendage stunning, there were significant differences in the duration of atrial fibrillation > 8 weeks (32.3% vs 75.5%, P < 0.001), left atrial diameter > 50 mm (29.0% vs 54.1%, P < 0.05), left atrial emptying fraction (31.5% +/- 7.8% vs 27.1% +/- 8.5%, P < 0.05), left ventricular ejection fraction < 50% (38.7% vs 67.6%, P < 0.05), maximum electrical energy (96.8 J +/- 65.8 J vs 156.8 J +/- 100.8 J, P < 0.01), cumulative electrical energy 146.8 J +/- 142.6 J vs 290.5 J +/- 242.1 J, P < 0.01) and number of electrical cardioversion shocks (1.7 +/- 0.9 vs 2.43 +/- 1.20, P < 0.05). However, backward stepwise multivariate logistic regression analysis identified as significant and independent predictors of left atrial appendage stunning only duration of atrial fibrillation > 8 weeks (OR = 7.249, 95% CI = 1.998 - 26.304, P < 0.01), left atrial diameter > 50 mm (OR = 3.896, 95% CI = 1.105 - 13.734, P < 0.05), left ventricular ejection fraction < 50% (OR = 4.465, 95% CI = 1.51713.140, P < 0.01) and cumulative energy of electrical cardioversion (OR = 1.004, 95% CI = 1.000 - 1.008, P < 0.05).
CONCLUSIONSDuration of atrial fibrillation > 8 weeks, left atrial diameter > 50 mm, left ventricular ejection fraction < 50%, and cumulative energy of electrical cardioversion are independent predictors of left atrial appendage stunning. Anticoagulation treatment should be individualized for patients undergoing electrical cardioversion to reduce the risk of both cardioversion-related thromboembolic events and hemorrhagic complications caused by warfarin treatment.