Analysis of the Detection Results of the Syphilis Specific Antibody in Blood Donors by Chemiluminescence Method and Enzyme Linked Immunosorbent Assay.
- Author:
Shou-Shan MEN
1
;
Fa-Kui SHANG
2
;
Chun-Hua HAN
2
;
Jin-Xiang SONG
3
;
Jing-Yin HAN
3
Author Information
- Publication Type:Journal Article
- From: Journal of Experimental Hematology 2017;25(1):226-230
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVETo investigate the application value of chemiluminescence method (CMIA) detection of Treponema pallidum (TP) specific antibodies in the blood test.
METHODSOver the same period the de novo enzyme linked immunosorbent assay (ELISA) and Abbott chemical luminescence method were used to detect the specific antibody of syphilis in a total of 66298 samples; TP-ELISA negative and TP-CMIA positive unpaid blood donation blood samples for syphilis specific antibody were detected and confirmed by Western blot.
RESULTSBlood samples from 66298 blood donors were detected by TP-ELISA, the positive samples was 250 and the positive rate was 0.38%. The positive samples of TP-CMIA was 297, the positive rate was 0.45%, the difference was statistically significant (P<0.05). The blood samples of 47 unpaid blood donors were confirmed by TP-Western blot method, as a result, 32 samples were positive, 15 were negative, and result detected by TP-ELISA method was negative.
CONCLUSIONTP-CMIA sensitivity is higher than that of TP-ELISA, and possesses higher sensitivity and specificity, and quick detection, simple operation, easy automation, suggesting greater application value in blood detection of Treponema pallidum.