Abstract:
BACKGROUNDPostoperative knee soft tissue irritation is a common complication after retrograde nail fixation of femoral fractures. Distal locking screw prominence is one of the causes for soft tissue irritation. This study aimed to determine whether the use of the femoral condyles tangential views improve the diagnostic accuracy compared with anteroposterior (A-P) view in detecting distal locking screw penetrations during retrograde femoral nailing.
METHODSThe angle between the sagittal plane and lateral aspect of the condyle and the angle between the sagittal plane and medial aspect of condyle were measured on computed tomography (CT) images. After the angles were measured and recorded, cadaveric femurs were used in a simulated surgical procedure. The retrograde femoral nail was inserted into the femur and placed distal locking screws, which were left 2, 4, and 6 mm proud of the medial and lateral condyles for each femur. A-P view, lateral condyle tangential view and medial condyle tangential view were obtained. All fluoroscopic images were recorded and sent to three observers blinded to the experimental procedure to determine whether screws penetrated the condyle cortex or not.
RESULTSAccording to the results of CT scan, the lateral condyle view was 20.88 ± 0.98° and the medial condyle view was 40.46 ± 3.14°. In the A-P view, we detected 0% at 2 mm penetration, 16.7% (lateral condyle screw) and 25.0% (medial condyle screw) at 4 mm, and 41.7% (lateral condyle screw) and 58.3% (medial condyle screw) at 6 mm. In the lateral tangential view, we detected 91.7% at 2 mm penetration of the lateral condyle and 100% at 4 mm and 6 mm. In the medial tangential view, we detected 66.7% at 2 mm penetration of the medial condyle and 100% at 4 mm and 6 mm. The femoral condyle tangential views provided significant improvement in detecting screw penetrations at all lengths (2, 4, and 6 mm) compared with the A-P view (P < 0.05).
CONCLUSIONSThe femoral condyles tangential views increased the accuracy of detecting screw penetrations on the medial and lateral condyles. Routine clinical use of the femoral condyles tangential views has the potential to increase accuracy in detecting distal locking screw penetration during retrograde femoral nailing.