Validated LC--MS/MS method for determination of YH-8, a novel PKnB inhibitor, in rat plasma and its application to pharmacokinetic study.
10.1016/j.apsb.2015.04.001
- Author:
Qianqian ZHAI
1
,
2
;
Jing PANG
3
;
Guoqing LI
3
;
Congran LI
3
;
Xinyi YANG
3
;
Liyan YU
3
;
Yucheng WANG
3
;
Jian LI
4
;
Xuefu YOU
3
Author Information
1. Institute of Medicinal Biotechnology, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100050, China
2. Key Laboratory of Sustainable Development of Marine Fisheries, Ministry of Agriculture, Yellow Sea Fisheries Research Institute, Chinese Academy of Fishery Sciences, Qingdao 266071, China.
3. Institute of Medicinal Biotechnology, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100050, China.
4. Key Laboratory of Sustainable Development of Marine Fisheries, Ministry of Agriculture, Yellow Sea Fisheries Research Institute, Chinese Academy of Fishery Sciences, Qingdao 266071, China.
- Publication Type:Journal Article
- Keywords:
LC–MS/MS;
Method validation;
Pharmacokinetics;
Rat plasma;
YH-8
- From:
Acta Pharmaceutica Sinica B
2015;5(5):467-472
- CountryChina
- Language:English
-
Abstract:
(E)-Methyl-4-aryl-4-oxabut-2-enoate (YH-8) is a novel PKnB protein kinase inhibitor with good anti-tuberculosis activity. To evaluate its pharmacokinetics in rats, a sensitive and selective high performance liquid chromatography-tandem mass spectrometric (LC--MS/MS) method has been developed and validated for the quantification of YH-8 in rat plasma for the first time. Samples were pre-treated using a liquid--liquid extraction with ethyl acetate and the chromatographic separation was performed on a C18 column by gradient elution with methanol--water as the mobile phase. YH-8 was detected using a tandem mass spectrometer in positive selected reaction monitoring (SRM) mode. Method validation revealed good linearity over the range of 1-500 ng/mL for YH-8 with a lower limit of quantification (LLOQ) of 1 ng/mL. Intra- and inter-day precision of YH-8 assay in rat plasma samples were 2.0%-6.8%, with accuracy of the method being 100.69%-106.18%. Stability test showed that when spiked into rat plasma, YH-8 was stable for 12 h at room temperature, for up to 15 days at -70 °C, and after three freeze-thaw cycles. Extracted samples were found to be stable over 12 h in an auto-sampler. The method was successfully applied to the pharmacokinetic study of YH-8 in rats after oral administration at 100 mg/kg and 200 mg/kg.