Abstract:
INTRODUCTIONElectrocardiographic (ECG) criteria for left ventricular hypertrophy (LVH), such as the Cornell and Sokolow-Lyon voltage criteria were derived from Western populations. However, their utility and accuracy for diagnosing echocardiographic LVH in Asian populations is unclear. The objective of this study was to assess the accuracy of ECG criteria for LVH in Asians and to determine if alternative gender-specific ECG cut-offs may improve its diagnostic accuracy.
MATERIALS AND METHODSECG and echocardiographic assessments were performed on 668 community-dwelling Asian adults (50.9% women; 57 ± 10 years) in Singapore. The accuracy of ECG voltage criteria was compared to echocardiographic LVH criteria based on the American Society of Echocardiography guidelines, and Asian ethnicity and gender-specific partition values.
RESULTSEchocardiographic LVH was present in 93 (13.6%) adults. Cornell criteria had low sensitivity (5.5%) and high specificity (98.9%) for diagnosing LVH. Modified gender specific cut-offs (18 mm in women, 22 mm in men) improved sensitivity (8.8% to 17.5%, 0% to 14.7%, respectively) whilst preserving specificity (98.2% to 94.2%, 100% to 95.8%). Similarly, Sokolow-Lyon criteria had poor sensitivity (7.7%) and high specificity (96.1%) for diagnosing LVH. Lowering the cut-off value from 35 mm to 31 mm improved the sensitivity in women from 3.5% to 14% while preserving specificity at 94.2%. A cut-off of 36 mm was optimal in men (sensitivity of 14.7%, specificity of 95.5%).