Two-year clinical outcomes following elective drug-eluting versus bare-metal stent implantation: results from a large single-center database.
- Author:
Run-lin GAO
1
;
Bo XU
;
Ji-lin CHEN
;
Yue-jin YANG
;
Shu-bin QIAO
;
Yang WANG
;
Ke-fei DOU
;
Xue-wen QIN
;
Min YAO
;
Hai-bo LIU
;
Yong-jian WU
;
Jin-qing YUAN
;
Jue CHEN
;
Shi-jie YOU
;
Jun DAI
;
Wei-hua MA
;
Wei LI
Author Information
- Publication Type:Journal Article
- MeSH: Adult; Aged; Angioplasty, Balloon, Coronary; mortality; Databases, Factual; Drug-Eluting Stents; adverse effects; Female; Follow-Up Studies; Humans; Male; Middle Aged; Myocardial Infarction; mortality; Stents; adverse effects
- From: Chinese Medical Journal 2009;122(19):2261-2267
- CountryChina
- Language:English
-
Abstract:
BACKGROUNDIn response to the increasing concern with the safety of the drug-eluting stent (DES), the present study aimed to evaluate the long-term safety and efficacy of DES used for a Chinese patient population.
METHODSAll patients, who underwent an index elective percutaneous coronary intervention with an implantation of either DES or bare-metal stent (BMS) in a single institution from April 2004 to December 2006, were included in the analysis. A propensity-score matching technique was applied to adjust and to minimize the impact of confounding factors.
RESULTSOverall, there were 1465 patients (20.2%) who had undergone an implantation of only BMS, and 5769 patients (79.8%) of only DES. The propensity-score matching technique set up 1321 pairs of patients for analysis. There were no significant differences between the rates of stent thrombosis (definite and probable) of the two groups (1.06% vs 1.21%, P = 0.8580). Although rates of mortality and myocardial infarction (MI) during the 2-year follow-up period had not differed significantly, rates of death/MI (3.0% vs 4.5%, P = 0.0263), target-lesion revascularization (TLR, 3.2% vs 8.5, P = 0.0001), target-vessel revascularization (TVR, 5.8% vs 9.5%, P < 0.0001) and any revascularization (10.0% vs 13.3%, P = 0.0066) were significantly lower for the DES group than for the BMS group. Among the patients in whom devices were implanted for off-label indications, the propensity-score matched rates of stent thrombosis, mortality, MI, and death/MI were not significantly different, while rates of TLR, TVR and any revascularization were significantly lower for the DES group than for the BMS group.
CONCLUSIONSDuring the 2 years of follow-up post stenting, DES use is associated with lower rates of death/MI, TLR, TVR and any revascularization, compared with BMS, in propensity-score matched Chinese patient populations. In the setting of off-label usage, DES use is also associated with similar advantages.