Comparative dosimetry of dental cone-beam computed tomography and multi-slice computed tomography for oral and maxillofacial radiology.
- Author:
Xing-min QU
1
;
Gang LI
;
Zu-yan ZHANG
;
Xu-chen MA
Author Information
- Publication Type:Journal Article
- MeSH: Cone-Beam Computed Tomography; Humans; Mandible; diagnostic imaging; Maxilla; diagnostic imaging; Multidetector Computed Tomography; Phantoms, Imaging; Radiation Dosage; Radiography, Dental; methods; Thermoluminescent Dosimetry
- From: Chinese Journal of Stomatology 2011;46(10):595-599
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVETo compare the effective radiation dose levels of cone beam computed tomography (CBCT) with those of multi-slice computed tomography (MSCT) when scanning the same maxillofacial regions.
METHODSThe effective doses of 2 CBCT (NewTom 9000 and DCT Pro) and 1 MSCT (bright speed edge select 8 slice) scanners were calculated using thermoluminescent dosimeters (TLD) that were placed in a head and neck phantom, and expressed according to the International Commission on Radiation Protection (ICRP) 2007 guidelines.
RESULTSEffective dose values ranged from 41.8 to 249.1 µSv for CBCT. The doses of MSCT scanning for maxilla, mandible and maxilla + mandible were 506.7, 829.9 and 1066.1 µSv, respectively. Dose levels of scanning only for maxilla or mandible were significantly lower than those for maxilla + mandible.
CONCLUSIONSWhen scanning the same maxillofacial regions, the dose levels for NewTom 9000 and DCT Pro CBCT images were lower than those for Bright speed edge select 8 slice MSCT images. Dose levels reduction could be obtained when smaller regions were scanned.