Clinical and ECG features of arrhythmogenic right ventricular cardiomyopathy: a retrospective analysis of 31 cases.
- Author:
Jie-lin PU
1
;
Hong-tao WANG
;
Tong-ku LIU
;
Ke-juan MA
;
Ning LI
;
Yan YAO
;
Jian-min CHU
;
Pi-hua FANG
;
Jian MA
;
Wei HUA
;
Shu ZHANG
;
Fang-zheng WANG
Author Information
- Publication Type:Journal Article
- MeSH: Adult; Arrhythmogenic Right Ventricular Dysplasia; diagnosis; therapy; Catheter Ablation; Defibrillators, Implantable; Electrocardiography; Female; Humans; Male; Middle Aged; Retrospective Studies; Young Adult
- From: Chinese Journal of Cardiology 2007;35(1):24-27
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVETo retrospectively analyze the clinical and electrocardiographic features of patients with arrhythmogenic right ventricular cardiomyopathy (ARVC).
METHODSThe clinical, electrocardiographic features and the efficacy of various therapies were analyzed in 31 patients (27 males) diagnosed as ARVC according to the criteria established by European Society of Cardiology.
RESULTSThe averaged age when the ARVC was first diagnosed was (34.7 +/- 9.4) years (19 - 58 years), palpitation was present in 28 patients (90.3%) and syncope in 13 patients (41.9%), a family history of sudden death was present in 1 patient. Dilatated right ventricle was documented in 29 patients by echocardiography and (or) magnetic resonance imaging (MRI), 2 of them with dilated left ventricles. ECG changes included: T wave inversion, mostly seen in precordial leads (100%); epsilon (epsilon) wave (54.8%); QRS duration >or= 110 ms in V(1) to V(3) (83.9%); reduced extremity amplitude (41.9%); the first degree of AV block (22.6%); sustained VT (100%) including 15 monomorphic VT (48.4%) and 16 polymorphic VT (51.6%). The mean values of QRS duration in leads of V(1 - 3) [(120.8 +/- 13.7) ms] was significantly longer than that in V(4 - 6) [(99.4 +/- 13.7) ms, P < 0.05]. Fourteen patients underwent radiofrequency catheter ablation (RFCA) with an immediate success rate of 78.6% (11/14). During follow up (18.3 +/- 10.2) months, VT reoccurred in 6 patients (54.5%). The remaining 17 patients were treated with conventional medications, 7 of them were medicated under implanted cardioverter defibrillator (ICD). During the follow-up (35.6 +/- 19.0) months, VT reoccurred in 11 patients (64.7%) and one patient died suddenly.
CONCLUSIONSARVC patients developed symptoms at mid-30s with significant ECG changes including appearance of an epsilon wave, T wave inversion and QRS duration >or= 110 ms in leads of V(1 - 3). The long term therapy efficacy was not satisfactory both for RFCA and conventional medications and ICD implantation should be recommended to patients with ARVC.