Efficacy of personalized endovascular repair using two stent-grafts for patients with Stanford B aortic dissection.
- Author:
Xiaoyong HUANG
1
;
Lianjun HUANG
1
;
Xi GUO
2
;
Yuguo XUE
1
;
Peng LI
1
;
Wenhui WU
1
;
Guangrui LIU
1
;
Tiezheng LI
1
;
Mingliang PENG
1
;
Qinglong ZENG
1
Author Information
- Publication Type:Journal Article
- MeSH: Acute Disease; Aneurysm, Dissecting; Aorta; Aortic Aneurysm; Aortic Aneurysm, Thoracic; therapy; Aortography; Blood Vessel Prosthesis; Blood Vessel Prosthesis Implantation; Endovascular Procedures; Humans; Prospective Studies; Retrospective Studies; Stents; Subclavian Artery; Thrombosis; Tomography, X-Ray Computed; Treatment Outcome
- From: Chinese Journal of Cardiology 2015;43(1):39-43
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVETo observe the feasibility and clinical efficacy of thoracic endovascular aortic repair (TEVAR) for patients with Stanford B aortic dissection using personalized two stent-grafts implantation (TSI).
METHODSThis retrospective review included 56 patients who underwent TSI during TEVAR for Stanford B aortic dissection from Jan 2012 to May 2013 in Beijing Anzhen hospital. There were 8 patients in acute phase (within 2 weeks from onset of symptoms), 11 patients in chronic phase (greater than 2 months following initial dissection) and 37 patients in subacute phase (between 2 weeks and 2 months from onset of symptoms). Infrarenal aorta was involved in 34 patients (60.7%) and suprarenal aorta involved in 22 patients (39.3%), the mean aortic lesion length was (226 ± 13)mm. Thoracic and abdominal aortic angiography was performed during operation to measure aortic diameters of proximal and distal landing zone, and the distance between them. The proximal stent-grafts were implanted in distal aorta to the origin of left subclavian artery with oversize rate of 10%-15% according to proximal landing zone according to procedural guideline. Then the distal newly customized large tapered stent-grafts were sequentially deployed according to the diameters of both the distal end of proximal stent and distal landing zone (aortic true lumen), and overlapping length of the two stent-grafts was more than 30 mm. Patients were followed-up at 3 months, 6 months, and yearly thereafter post operation.
RESULTSTSI procedure was successful in all patients and 122 stent-grafts were implanted. The mean length of implanted stent-grafts was (197.6 ± 20.3)mm. The mean diameter taper span was (7.5 ± 1.8)mm with proximal oversize rate of (12.8 ± 3.4)% and distal oversize rate of (11.2 ± 4.1)%. The mean angle between the distal end of stent and aorta was (2.3 ± 1.3)°. The diameter of proximal and distal landing zone, and angle between the distal end of stent and aorta remained unchanged during follow up (mean: (10.0 ± 4.0) months). The total thrombosis rate of the false lumen was 98.2% (55/56), thrombosis rate of stent segment was 82.1% (46/56) . Stent-related complications were observed in 2 patients (3.6%) , including acute spinal cord ischemia due to paraplegia (n = 1) and malposition of distal stent (n = 1).
CONCLUSIONSEncouraging short-term outcomes are obtained from current personalized two stent-grafts implantation strategy for patients with Stanford B aortic dissection. Further prospective clinical studies are warranted to evaluate the long-term efficacy of this procedure.