Comparison of dentin nanoleakage among six adhesives.
- Author:
San-jun ZHAO
1
;
Ji-hua CHEN
;
Wei WU
;
Yu XIONG
Author Information
- Publication Type:Journal Article
- MeSH: Dental Leakage; Dentin; ultrastructure; Dentin-Bonding Agents; classification; Humans; In Vitro Techniques; Materials Testing; Microscopy, Electron, Transmission; Molar
- From: Chinese Journal of Stomatology 2005;40(6):500-503
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVETo evaluate the nanoleakage appearance in 6 dentin adhesives.
METHODSSuperficial occlusal dentin of 12 human molars without caries extracted freshly was exposed with 600-grit SiC papers under running water. Six adhesives were applied to dentin surfaces according to the manufacturers' instructions. The bonded teeth were sectioned occluso-gingivally into 0.9-mm-thick serial slabs that were stored in ammoniacal silver nitrate solution in the dark for 24 h and prepared for transmission electron microscope. The extent of nanoleakage among 6 dentin adhesives was measured and compared using one-way ANOVA.
RESULTSThe nanoleakage was observed obviously at the dentin-resin interfaces of all 6 adhesives. The average dentin nanoleakage values of Group A [BangDuo, (16.09 +/- 2.08)%], Group B [Single Bond, (13.39 +/- 1.81)%], and Group C [Prime&Bond NT, (11.27 +/- 1.94)%] were all significantly different (P < 0.05). There was no significant difference in the dentin nanoleakage between Group D [B(1), (12.13 +/- 2.11)%] and Group E [Clearfil SE Bond, (12.35 +/- 2.60)%], but both of them were lower than Group F [Adper Prompt, (14.93 +/- 2.67)%].
CONCLUSIONSThe nanoleakage phenomena at the dentin-resin interface were all observed diversely in the contemporary dental adhesives.