Image quality stability of whole-body diffusion weighted imaging.
- Author:
Yun-bin CHEN
1
;
Chun-miao HU
;
Jing ZHONG
;
Fei SUN
Author Information
- Publication Type:Journal Article
- MeSH: Adult; Aged; Diffusion Magnetic Resonance Imaging; methods; Echo-Planar Imaging; methods; Female; Humans; Image Processing, Computer-Assisted; methods; Male; Middle Aged; Reproducibility of Results; Respiration; Whole Body Imaging; methods
- From: Chinese Medical Sciences Journal 2009;24(2):122-126
- CountryChina
- Language:English
-
Abstract:
OBJECTIVETo assess the reproducibility of whole-body diffusion weighted imaging (WB-DWI) technique in healthy volunteers under normal breathing with background body signal suppression.
METHODSWB-DWI was performed on 32 healthy volunteers twice within two-week period using short TI inversion-recovery diffusion-weighted echo-planar imaging sequence and built-in body coil. The volunteers were scanned across six stations continuously covering the entire body from the head to the feet under normal breathing. The bone apparent diffusion coefficient (ADC) and exponential ADC (eADC) of regions of interest (ROIs) were measured. We analyzed correlation of the results using paired-t-test to assess the reproducibility of the WB-DWI technique.
RESULTSWe were successful in collecting and analyzing data of 64 WB-DWI images. There was no significant difference in bone ADC and eADC of 824 ROIs between the paired observers and paired scans (P>0.05). Most of the images from all stations were of diagnostic quality.
CONCLUSIONThe measurements of bone ADC and eADC have good reproducibility. WB-DWI technique under normal breathing with background body signal suppression is adequate.