The change of renin, endothelin and prostaglandin in blood during long time left ventricular assist.
- Author:
Lian-wei TONG
1
;
Bing REN
;
Xiao-dong ZHU
Author Information
- Publication Type:Journal Article
- MeSH: Animals; Dogs; Endothelins; blood; Heart-Assist Devices; Models, Animal; Prostaglandins; blood; Renin; blood; Ventricular Function
- From: Chinese Journal of Surgery 2004;42(6):355-357
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVETo monitor the change of renin, endothelin and 6-keto-prostaglandin F1alpha in canine during left ventricular assist (LVA).
METHODSEight canines were assisted by left assist ventricular device for 9 hours. The level of renin, endothelin and 6-keto-prostaglandin f1alpha in plasma were measured by radioimmunity analysis before assisting (control group) and at 3 hours, at 6 hours, at 9 hours after assisting.
RESULTSThe level of endothelin in plasma didn't dropped remarkably as LVA proceeded in which there was not differency in statistical diffency compared with control group[(51 +/- 11) ng/L, (42 +/- 8) ng/L, t = 0.926, P > 0.05]; The level of renin in plasma reached the summit at 3 hours during LVA compared with control group (3,036 +/- 1,411) ng/L, (1,783 +/- 467) ng/L, t = 5.013, P < 0.01) and later show dropping tendency without statistical differency at 9 hours (1 944 +/- 883) ng/L (t = 0.644, P > 0.05); The level of 6-keto-prostaglandin f1alpha in plasma at 3 hours during assisting increased remarkably [(75 +/- 17) ng/L, t = 1.411, P < 0.05), at 6 hours reached summit [(92 +/- 18)ng/L, t = 3.533, P < 0.01) and at 9 hours show dropping tendency with significant differency compared with control group (90 +/- 22) ng/L, t = 2.516, P < 0.05).
CONCLUSIONDuring 9 hours LVA, endothelin didn't dropped remarkably compared with control group and the endothelium released renin with transient increase, prostaglandin with consistent increase.